PHOENIX VE.DIRECT INVERTERS
The new serie of Victron Energy Phoenix VE.Direct inverters comes to replace the well know Phoenix inverters, including new functionalities and versatility to this product:
VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, macbooks and other devices (VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Output voltage 210 - 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage and current alarms
Proven reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short circuit proof and protected against overheating, whether due to overload or high ambient temperature.
High start-up power
Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset value. Once in standby the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote on/off
A remote on/off switch can be connected to a two pole connector, or between battery plus and the left hand contact of the two pole connector.
LED diagnosis
Now you can get information of the inverter status thanks to the leds. Please see manual for a description.
To transfer the load to another AC source: the automatic transfer switch
For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption.
Available with different output sockets
Schuko
UK (BS-1363)
AU/NZ (3112)
IEC-320 (male plug included)
Screw terminals
No special tools needed for installation
Specifications
Phoenix VE.Direct |
12/250 24/250 48/250 |
12/375 24/375 48/375 |
12/500 24/500 48/500 |
12/800 24/800 48/800 |
12/1200 24/1200 48/1200 |
Cont. Power 25º C | 250 VA | 375 VA | 500 VA | 800 VA | 1200 VA |
Cont. Power at 25 / 40º C | 200 / 150 W | 300 / 250 W | 400 / 350 W | 650 / 560 W | 1000 / 850 W |
Peak Power | 350 W | 700 W | 900 W | 1500 W | 2200 W |
Output AC voltage | 230 Vac +/- 3% | ||||
Output Frequency | 50 or 60 Hz (adjustable) +/- 0,1% | ||||
Input voltage range | 12v: 9,2 - 17 vdc / 24v: 18,4 - 34 Vdc / 48v: 36,8 - 62 Vdc | ||||
DC low shut down | 9,3 / 18,6 / 37,2 Vdc (adjustable) | ||||
DC low restart and alarm | 10,9 / 21,8 / 43,6 Vdc (adjustable) | ||||
Battery charged detect | 14 / 28 / 56 Vdc (adjustable) | ||||
Max. eficiency | 87 / 88 / 88 % | 89 / 89 / 90 % | 90 / 90 / 91 % | 90 / 90 / 91 % | 91 / 91 / 92 % |
Zero-load consumption | 4,2 / 5,2 / 7,9 W | 5,6 / 6,1 / 8,5 W | 6 / 6,5 / 9,0 W | 6,5 / 7,0 / 9,0 W | 7 / 8 / 9 W |
ECO mode consumption | 0,8 / 1,3 / 2,5 W | 0,9 / 1,4 / 2,6 W | 1 / 1,5 / 3,0 W | 1 / 1,5 / 3,0 W | 1 / 1,5 / 3,0 W |
ECO mode interval | Adjustable | ||||
Protectión |
Output short circuit Overload Battery voltage too hight Battery voltage too low Temperature too high DC ripple too high |
||||
Temperature | -40 to +60 ºC (fan assisted cooling) Derate 3% per ºC above 40 ºC | ||||
Humidity | max 95 % (non.condensing) | ||||
Enclosure | |||||
Material & Colour | Steel chassis and plastic cover (Blue RAL 5012) | ||||
Battery-connection | Screw terminals | ||||
Maximum cable cross-section | 10 mm2 | 10 mm2 | 10 mm2 | 25 / 10 / 10 mm2 | 32 / 25 / 25 mm2 |
IP Protection | IP21 | ||||
weight | 2,4 Kg | 3,0 Kg | 3,9 Kg | 5,5 Kg | 7,4 Kg |
Dimensions (mm) | 86 x 165 x 260 | 86 x 165 x 260 | 86 x 172 x 275 |
12V: 105 x 230 x 325 105 x 216 x 305 |
12V: 117 x 232 x 362 117 x 232 x 327 |
Standards | |||||
Safety | EN/IEC 60335*1 / EN/IEC 62109-1 | ||||
EMC | EN 55014-1 / EN55014-2 / EN 61000-6-1 / IEC 61000-6-3 | ||||
Automotive directive | 2004/104/EC EN 50498 |