BLUESOLAR MPPT
Ultra fast Maximum Power Point Tracking (MPPT)
Especially in case of a clouded sky, when light intensity is changing continuously, an ultra fast MPPT controller will improve energy harvest by up to 30% compared to PWM charge controllers and by up to 10% compared to slower MPPT controllers.
Load output
Over-discharge of the battery can be prevented by connecting all loads to the load output. The load output will disconnect the load when the battery has been discharged to a preset voltage.
Alternatively, an intelligent battery management algorithm can be chosen: see BatteryLife.
The load output is short circuit proof.
Some loads (especially inverters) can best be connected directly to the battery, and the inverter remote control connected to the load output. A special interface cable may be needed, please see the manual for compatible products.
BatteryLife: intelligent battery management
When a solar charge controller is not able to recharge the battery to its full capacity within one day, the result is often that the battery will be continually be cycled between a “partially charged” state and the “end of discharge” state. This mode of operation (no regular full recharge) will destroy a leadacid battery within weeks or months.
The BatteryLife algorithm will monitor the state of charge of the battery and, if needed, day by day slightly increase the load disconnect level (i. e. disconnect the load earlier) until the harvested solar energy is sufficient to recharge the battery to nearly the full 100%. From that point onwards the load disconnect level will be modulated so that a nearly 100% recharge is achieved about once every week.
Automatic battery voltage recognition
The MPPT 75/15 will automatically adjust to your system voltage.
75/10 - 100/20 Specifications
|
MPPT 75/10 |
MPPT 75/15 |
MPPT 100/15 |
MPPT 100/20 | MPPT 100/20-48 | |
Performance |
||||||
Battery voltage |
12 / 24 Vdc |
12 / 24 Vdc |
12 / 24 Vdc |
12 / 24 Vdc | 12 / 24 / 48 Vdc | |
Self consumption |
12V: 25 mA - 24 V: 15 mA |
12V: 25 mA - 24 V: 15 mA 48V: 10 mA |
||||
DC input |
||||||
Maximum PV power 12V |
145 W |
220 W |
220 W |
290 W | 290 W | |
Maximum PV power 24V |
290 W |
440 W |
440 W |
580 W | 580 W | |
Maximum PV power 48V | n.d. | n.d. | n.d. | n.d. | 1160 W | |
Max PV open circuit voltage |
75 Vdc |
75 Vdc |
100 Vdc |
100 Vdc | 100 Vdc | |
Peak efficiency |
98 % |
98 % |
98 % |
98 % | 98 % | |
DC Output |
||||||
Load current |
15 Amp max |
15 Amp max |
15 Amp max |
20 Amp. max. | 20 A / 20 A / 1 A max. | |
Absorption voltage |
14,4 / 28,8 Vdc |
14,4 / 28,8 Vdc |
14,4 / 28,8 Vdc |
14,4 / 28,8 Vdc | 14,4 / 28,8 / 57,6 Vdc | |
Float voltage |
13,8 / 27,6 Vdc |
13,8 / 27,6 Vdc |
13,8 / 27,6 Vdc |
13,8 / 27,6 Vdc | 13,8 / 27,6 / 55,2 Vdc | |
Charge algorithm |
Multi stage adaptative | |||||
Temperature compensation |
-16 mV/ºC rep. -32mV/ºC |
|||||
Continuos peak load current |
13 A |
15 A |
15 A |
20 A | 20 A | |
Low voltage load disconnect |
11,1 / 22,2 / 44,4 V ó 11,8 / 23,6 / 57,6 V or BatteryLife algorithm |
|||||
Low voltage load reconnect |
13,1 V / 26,2 / 52,4 V ó 14 V / 28 / 56 V or BatteryLife algorithm |
|||||
Ambiental specifications |
||||||
Operating temperature |
-30 a +60 ºC. Full rated output up to 40º C |
|||||
Humidity |
95%, non condensing |
|||||
Enclosure and Environmental |
||||||
Data communication port |
VE.Direct |
|||||
Power terminals |
6 mm2 |
6 mm2 |
6 mm2 |
6 mm2 | 6 mm2 | |
Protection category |
IP65 / IP22 (conections) |
|||||
Dimensions |
100 x 113 x 40 mm |
100 x 113 x 50 mm | 100 x 113 x 60 mm | |||
Weight |
0,5 Kg |
0,6 Kg | 0,65 Kg | |||
Mounting |
Vertical wall mount. Indoor only |
|||||
Standards |
||||||
Security |
EN 62109-1, UL 1741, CSA C22.2 |
100/30 - 100/50 Specifications
|
MPPT 100/30 |
MPPT 100/50 |
|
Performance |
|||
Battery voltage |
12 / 24 Vdc |
12 / 24 Vdc |
|
Self consumption |
12V: 30 mA. - 24V: 20 mA. |
||
DC input |
|||
Maximum PV power 12V |
440 W (15 to 80 Vdc)* |
700 W (15 to 70 Vdc resp. 95V)* |
|
Maximum PV power 24V |
880 W (30 to 80 Vdc)* |
1400 W (30 to 70 Vdc resp. 95V)* |
|
Max PV open circuit voltage |
100 Vdc |
100 Vdc |
|
Peak efficiency |
98 % |
98 % |
|
DC Output |
|||
Absorption voltage |
14,4 / 28,8 Vdc |
14,4 / 28,8 Vdc |
|
Float voltage |
13,8 / 27,6 Vdc |
13,8 / 27,6 Vdc |
|
Charge algorithm |
Multi stage adaptative |
||
Temperature compensation |
-16 mV/ºC rep. -32mV/ºC |
||
Load current |
30 A |
50 A |
|
Ambiental specifications |
|||
Operating temperature |
-30 a +60 ºC. Full rated output up to 40º C |
||
Humidity |
95%, non condensing |
||
Enclosure and Environmental |
|||
Data communication port |
VE.Direct |
||
Terminals |
13 mm2 |
13 mm2 |
|
Protection category |
IP43 / IP22 (conections) |
||
Dimensions |
130 x 186 x 70 mm |
||
Weight |
1,30 Kgr |
||
Mounting |
Vertical wall mount. Indoor only |
||
Standards |
|||
Security |
EN62109 |
150/35 - 150/100 Specifications
|
MPPT 150/35 | MPPT 150/45 | MPPT 150/60 | MPPT 150/70 |
MPPT 150/100 VE.Can |
|||||
Performance |
||||||||||
Battery voltage |
12 / 24 / 48 Vdc | 12/24/48 Vdc | 12/24/48 Vdc | 12/24/48 Vdc | 12/24/48 Vdc | |||||
Self consumption |
12V: 25mA - 24V: 15 mA - 48V: 10 mA |
10 mA |
30 mA |
|||||||
DC input |
||||||||||
Maximum PV power 12V |
500 W | 650 W | 860 W | 1000 W | 1450 W | |||||
Maximum PV power 24V |
1000 W | 1300 W | 1720 W | 2000 W | 4350 W | |||||
Maximum PV power 48V | 2000 W | 2600 W | 3440 W | 4000 W | 5800 W | |||||
Max PV open circuit voltage |
150 Vdc | 150 Vdc | 150 Vdc | 150 Vdc | 150 Vdc | |||||
Peak efficiency |
98 % |
98 % |
98 % |
98 % | 98 % | |||||
DC Output |
||||||||||
Absorption voltage |
14,4 / 28,8 / 57,6 Vcc (adjustable) |
|||||||||
Float voltage |
13,8 / 27,6 / 55,2 Vcc (adjustable) |
|||||||||
Charge algorithm |
Multi stage adaptative |
|||||||||
Temperature compensation |
-16 mV/ºC / -32mV/ºC / -64 mV/ºC |
|||||||||
Load current |
35 A | 45 A | 60 A | 70 A | 100 A | |||||
Max. PV short circuit current | 40 A | 50 A | 50 A | 50 A | 70 A | |||||
Protection | PV Reverse polarity / Output Short Circuit / Over temperature | |||||||||
Ambiental specifications |
||||||||||
Operating temperature |
-30 to +60 ºC. Full rated output up to 40º C |
|||||||||
Humidity |
95%, non condensing |
|||||||||
Enclosure and Environmental |
||||||||||
Data communication port |
VE.Direct |
VE.Can | ||||||||
Terminals |
13 mm2 |
35 mm2 (Tr) 2 x MC4 (MC4) |
35 mm2 (Tr) 2 x MC4 (MC4) |
35 mm2 (Tr) 2 x MC4 (MC4) |
35 mm2 (Tr) 3 x MC4 (MC4) |
|||||
Protection category |
IP43 / IP22 (conections) |
|||||||||
Dimensions |
130 x 186 x 70 mm |
Tr: 185 x 250 x 95 mm MC4: 215 x 250 x 95 mm |
216 x 295 x 103 mm |
|||||||
Weight |
1,25 Kgr |
3 Kgr | 3 Kgr | |||||||
Mounting |
Vertical wall mount. Indoor only |
|||||||||
Standards |
||||||||||
Security |
EN 62109-1, UL 1741, CSA C22.2 |
Do you want more information about this product?
bornay@bornay.com | (+34) 965 560 025 | Skype