SUNNY TRIPOWER X
The new Sunny Tripower X is the innovative system solution for commercial and large home PV systems.
The integrated System Manager function with direct access to Sunny Portal powered by ennexOS monitors up to five SMA inverters and one energy meter. This enables the dynamic closed-loop control of active and reactive power via SMA Dynamic Power Control.
Thanks to the wide input voltage range and the high input current capability, it is compatible with the latest generation of high-performance PV modules.
The innovative enclosure design ensures efficient cooling of the electronic components and thus guarantees maximum lifetime of the Sunny Tripower X.
Commissioning can be performed quickly and easily as well as centrally for all devices in the system.
During operation, users benefit from integrated software solutions: SMA ShadeFix increases PV yields even in the event of partial shading, while SMA ArcFix detects electric arcs effectively and can reliably reduce the risk of fire.
Integrated system manager
- Monitoring and control for up to 5 inverters (max. 135 kVA) included
- Direct access to Sunny Portal powered by ennexOS
- SMA Dynamic Power Control
Safety included
- SMA ArcFix arc-fault circuit interrupter
- DC overvoltage protection
- Simplified grid and PV system protection
Maximum yields
- Yield increase through integrated SMA ShadeFix
- I-V generator diagnostics
- Direct selling with SMA SPOT
- SMA Smart Connected
More flexibility
- 3 MPP trackers
- High input current for highperformance PV modules
- Modular design allowing expansion for future energy management functions
Specifications
Sunny Tripower X 12 | Sunny Tripower X 15 | Sunny Tripower X 20 | Sunny Tripower X 25 | |
Input (CC) | ||||
Máx. PV Array power | 18.000 Wp STC | 22.500 Wp STC | 30.000 Wp STC | 37.500 Wp STC |
Max. input voltage | 1000 V | 1000 V | 1000 V | 1000 V |
MPP voltage range | 206 to 800 V | 257 to 800 V | 340 to 800 V | 430 to 800V |
Rated input voltage | 580 V | 580 V | 580 V | 580 V |
Min. input voltage / Initial input voltage | 150 V / 188 V | 150 V / 188 V | 150 / 188 V | 150 / 188 V |
Max. input current per MPP tracker | 24 A | 24 A | 24 A | 24 A |
Max. short-circuit current per MPP tracker | 35 A | 35 A | 35 A | 35 A |
Number of independent MPP trackers / strings per MPP tracker | 3 / 2 | 3 / 2 | 3 / 2 | 3 / 2 |
Output AC | ||||
Rated power AC | 12.000 W | 15.000 W | 20.000 W | 25.000 W |
Apparent power | 12.000 VA | 15.000 VA | 20.000 VA | 25.000 VA |
Nominal voltage |
3 / N / PE: 220 V / 380 V 3 / N / PE: 230 V / 400 V |
|||
Voltage range | 176 to 275 V / 304 to 477 V | |||
Grid Frequency | 50 - 60 Hz | |||
Frecuency range | 44 - 66 Hz | |||
Max. output current | 36,6 A | 36,6 A | 36,6 A | 36,6 A |
Rated output current | 17,4 A | 21,7 A | 29 A | 26,2 A |
Power factor at rated power | 1 | |||
Adjustable displacement power factor |
1 / 0.8 overexcited to 0.8 underexcited |
|||
THD |
< 3% |
|||
Injection phases / phases | 3 / 3 | |||
Efficiency | ||||
Max. efficiency | 98,2 % | 98,2 % | 98,2 % | 98,2 % |
European efficiency | 97,6 % | 97,8 % | 97,9 % | 98,0 % |
Protective Devices | ||||
Input-side disconnection point | Yes | Yes | Yes | Yes |
Ground fault monitoring | Yes | Yes | Yes | Yes |
Grid monitoring | Yes | Yes | Yes | Yes |
DC Surge arrester (type 2, type 1/2) | Optional | Optional | Optional | Optional |
DC reverse polarity protection | Yes | Yes | Yes | Yes |
AC Short-circuit current capability | Yes | Yes | Yes | Yes |
All-pole sensitive residual-current monitoring units | Yes | Yes | Yes | Yes |
Arc-fault circuit interrupter (AFCI) | Yes | Yes | Yes | Yes |
I-V Generator diagnostics | Yes | Yes | Yes | Yes |
Protection class (according to IEC 62109-1) |
I | I | I | I |
Overvoltage category (according to IEC 62109-1) | AC: III; DC: II | AC: III; DC: II | AC: III; DC: II | AC: III; DC: II |
General Data | ||||
Dimmensions | 728 x 762 x 266 mm | |||
Weight | 35 Kg | |||
Operating temperature range | -25 to 60 ºC | |||
Noise emission, maixum (1 m) | < 65 dB | |||
Self-consumption (night) | < 5 W | |||
Topology | No galvanic issolation | |||
Cooling concept | Opticool | |||
Degree of protection (according to IEC 60529) |
IP65 | |||
Climatic category (according to IEC 60721-3-4) |
4K26 | |||
Max. permissible value for relative humidity (non-condensing) |
100% (sin condensación) | |||
Features / Functions / Accessories | ||||
DC Connection | SUNCLIX | |||
AC Connection | Spring-cage terminal | |||
LES displays (Status / Fault / Communication) | Yes | Yes | Yes | Yes |
Ethernet | Yes, 2 ports. | Yes, 2 ports | Yes, 2 ports | Yes, 2 ports |
Wlan | Yes | Yes | Yes | Yes |
RS485 | Optional | Optional | Optional | Optional |
Data protocols | SMA Modbus / SunSpec Modbus / Speedwire | |||
Multi-function relay | Yes | Yes | Yes | Yes |
Slor for expansion module | Yes, 1 port | Yes, 1 port | Yes, 1 port | Yes, 1 port |
Number of digital inputs | 6 | 6 | 6 | 6 |
SMA ShadeFix | Yes | Yes | Yes | Yes |
Integrated plant control | Yes | Yes | Yes | Yes |
Q on demand 24/7 | Yes | Yes | Yes | Yes |
Off-grid capable | Yes | Yes | Yes | Yes |
SMA Hybrid controller compatible | Yes | Yes | Yes | Yes |
Warranty | 5 years (Optional 10, 15, 20 years) | |||
Certificates and approvals |
VDE AR-N 4105/4110:2018, EN 50549-1/-2:2018, CE, UKCA |
|||
System manager function | ||||
Total number of supported devices, of which: | 6 | |||
Max. number of supported SMA inverters | 5 | |||
Max. number of supported energy meters | 1 | |||
Maximum nominal system power of PV inverters | 135 kVA | |||
Centralized commissioning of all devices in the system | Yes | |||
Remote parameterization of SMA devices with Sunny Portal, by ennexOS | Yes | |||
SMA Dynamic power control (Example: Zero injection) | Optional |
Downloads
Catálogo SMA Sunny Tripower X
SMA Sunny Tripower X brochure
Do you want more information about this product?