SUNNY BOY 3.0 / 3.6 / 4.0 / 5.0 / 6.0
The new Sunny Boy 3.0 – 6.0 succeeds the globally successful Sunny Boy 3000 – 5000TL. It is more than just a PV inverter: with the integrated SMA Smart Connected service, it offers all-round comfort for PV system operators and installers alike. The automatic inverter monitoring by SMA analyzes operation, reports irregularities and thus minimizes downtime.
The Sunny Boy is ideally suited to solar power generation in private homes. Thanks to its extremely light design and location of the external connections, the device can be quickly installed and easily commissioned thanks to the intuitive webserver.
Current communication standards mean that intelligent energy management solutions as well as SMA storage solutions can be flexibly added to the inverter at any time.
The integrated service for ease and comfort.
SMA Smart Connected* is the free monitoring of the inverter via the SMA Sunny Portal. If there is an inverter fault, SMA proactively informs the PV system operator and the installer. This saves valuable working time and costs.
With SMA Smart Connected, the installer benefits from rapid diagnoses by SMA. They can thus quickly rectify the fault and score points with the customer thanks to the attraction of additional services.
- ACTIVATION OF SMA SMART CONNECTED
During registration of the system in the Sunny Portal, the installer activates SMA Smart Connected and benefits from the automatic inverter monitoring by SMA.
- AUTOMATIC INVERTER MONITORING
SMA takes on the job of inverter monitoring with SMA Smart Connected. SMA automatically checks the individual inverters for anomalies around the clock during operation. Every customer thus benefits from SMA’s long years of experience.
- PROACTIVE COMMUNICATION IN THE EVENT OF FAULTS
After a fault has been diagnosed and analyzed, SMA informs the installer and end customer immediately by e-mail. Everyone is thus optimally prepared for the troubleshooting. This minimizes the downtime and saves time and money. The regular power reports also provide valuable information about the overall system.
- REPLACEMENT SERVICE
If a replacement device is necessary, SMA automatically supplies a new inverter within one to three days of the fault diagnosis. The installer can contact the PV system operator of their own accord and replace the inverter.
- PERFORMANCE SERVICE
The PV system operator can claim compensation from SMA if the replacement inverter cannot be delivered within three days.
Specifications
Technical Data | Sunny Boy 3.0 | Sunny Boy 3.6 | Sunny Boy 4.0 | Sunny Boy 5.0 | Sunny Boy 6.0 |
Input (DC) | |||||
Max. generator power | 5500 Wp | 5500 Wp | 7500 Wp | 7500 Wp | 9000 Wp |
Max. input voltage | 600 V | ||||
MPP Voltage range | 110 to 500 V | 130 to 500 V | 140 to 500 V | 175 to 500 V | 210 to 500 V |
Rated input voltage | 365 V | ||||
Min. input voltage / initial input voltage | 100 V / 125 V | ||||
Max. input current input A / input B | 15 A / 15 A | ||||
Max. input current per string input A / input B | 15 A / 15 A | ||||
Number of independent MPP inputs | 2 | ||||
Strings per MPP input | A: 2 - B: 2 | ||||
Output (AC) | |||||
Rated power (at 230 V, 50 Hz) | 3000 W | 3680 W | 4000 W | 5000 W 1) | 6000 W |
Max. apparent power AC | 3000 VA | 3680 VA | 4000 VA | 5000 VA 1) | 6000 VA |
Nominal AC voltage / Range | 220V, 230V, 240V, / 180 to 280 V | ||||
AC Power frequency / range | 50 Hz, 60 Hz / - 5 Hz to + 5 Hz | ||||
Rated grid voltage / Rated power frequency | 230 V / 50 Hz | ||||
Max. output current | 16 A | 16 A | 22 A 2) | 22 A 2) | 26,1 A |
Power factor at rated power | 1 | ||||
Adjustable displacement power factor | 0,8 overexcited to 0,8 underexited | ||||
Feed-in phases / connection phases | 1 / 1 | ||||
Efficiency | |||||
Max. efficiency | 97,0 % | 97,0 % | 97,0 % | 97,0 % | 97,0 % |
European Efficiency | 96,4 % | 96,5 % | 96,5 % | 96,5 % | 96,6 % |
Protective devices | |||||
Input-side disconnection point | Standard | ||||
Ground fault monitoring | Standard | ||||
Grid monitoring | Standard | ||||
DC reverse polarity protection | Standard | ||||
AC short circuit current capability | Standard | ||||
All pole sensitive residual current monitoring unit | Standard | ||||
Protection class (as per IEC 62103) | I | ||||
Overvoltage category (according to IEC 60664-1) | III | ||||
General Data | |||||
Dimension ( W / H / D) | 435 / 470 / 176 mm | ||||
Weight | 16 Kg | ||||
Operating temperature range | - 25 to 60 ºC | ||||
Noise emission, typical | 25 dB (A) | ||||
Self-consumption (at night) | 1 W | ||||
Topology | Transformerless | ||||
Cooling method | Convection | ||||
Degree of protection (as per IEC 60529) | IP65 | ||||
Climatic category (as per IEC 60721-3-4) | 4K4H | ||||
Max. permissible value for relative humidity |
100% (non-condensing) |
||||
Equipment | |||||
DC connection / AC Connection | SUNCLIX / AC Connector | ||||
Display | Via Smartphone, tablet or laptop | ||||
Interfaces | WLAN, Speedwire / Webconnect | ||||
Warranty |
5 Years (10, 15, 20 years optional) |
||||
Certificates and approvals |
AS 4777, C10/11, CE, CEI 0-2-1, EN 50438, G59/3, G83/2, DIN EN 62109 / IEC 62109, NEN-EN50438, RD1699, SI 4777, UTE C15712, VDE-AR-N 4105, VDE0126-1-1, VFR 2014 |
||||
Type designation | SB3.0-1AV-41 | SB3.6-1AV-41 | SB4.0-1AV-41 | SB5.0-1AV-41 | SB6.0-1AV-41 |
1) 4600 W / 4600 VA for VDE-AR-N 4105
2) AS 4777: 21,7 A
Do you want more information about this product?