SYNERGY THREE PHASES INVERTERS
Three Phase Inverters with Synergy Technology
SolarEdge’s expanded offering of three phase inverters with synergy technology up to 100kW combines large capacity with ease of installation. The inverter design is based on small, lightweight, and easy-to-carry primary and secondary units. They are wall mounted for a minimal footprint, with installation only requiring a one or two-person crew.
No crane or special tools are needed when installing the inverter, unlike alternative large capacity inverters on the market today, which are heavy, bulky, and difficult to install. Installing SolarEdge’s large capacity inverters instead of using multiple, smaller capacity inverters will further reduce setup times and costs.
This new generation of SolarEdge three phase inverters is available in the following sizes: 50kW, 55kW, and 82.8kW.
Easy Inverter Commissioning with Inverter SetApp
Inverter commissioning has never been this easy. Activating, commissioning, and configuring your inverter is now done directly through your smartphone using the SolarEdge SetApp mobile application.
Take your inverter commissioning to the next level.
Key Benefits:
-
Easy two-person installation – each unit mounted separately, equipped with cables for simple connection between units
-
Balance of System and labor reduction compared to using multiple smaller string inverters
-
Independent operation of each unit enables higher uptime and easy serviceability
-
No wasted ground area: wall/rail mounted or horizontally mounted under the modules (10 ̊ inclination)
-
Built-in module-level monitoring with Ethernet or cellular GSM
-
Fixed voltage inverter for superior efficiency (98.3%) and longer strings
-
Integrated Connection Unit with optional integrated DC Safety Switch – eliminates the need for external DC isolators
-
Built-in RS485 Surge Protection, to better withstand lightning events
-
Advanced safety features - integrated arc fault protection and optional rapid shutdow
Specifications
SE50K | SE55K | SE82,8 | ||||||
OUTPUT | ||||||||
Rated AC Power Output | VA | 50000 | 55000 | 82800 | ||||
Máximum AC Power Output | VA | 50000 | 55000 | 82800 | ||||
AC Output Voltage Line to line; Line to Neutral (Nominal) |
Vac | 380 / 220 ; 400 / 230 | ||||||
AC Ouput Voltage - Line to Neutral range | Vac |
304 - 437 / 176 - 253 ; 320 - 460 /184 - 264.5
|
||||||
AC Frequency (Nominal) | Hz | 50 / 60 ± 5 | ||||||
Max. Continuous Output Current (per phase) | A | 76 | 80 | 120 | ||||
Grids Supported - Three Phase | V | 3 / N / PE (WYE with Neutral) | ||||||
Maximum residual current injection | mA | 250 per unit | ||||||
Protections | Utility monitoring, Islanding Protection, Configurable Power FactorCountry configurable Thresholds | |||||||
INPUT |
||||||||
Maximum DC Power (Module STC) Inverter / Unit | W | 67500 / 33750 | 74500 / 37250 | 111750 / 37250 | ||||
Transformer-less, Ungrounded | Yes | |||||||
Maximum input voltage | Vdc | 900 | ||||||
Nominal DC input voltage | Vdc | 750 | ||||||
Maximum Input Current | Adc | 2 x 37 | 2 x 40 | 3 x 40 | ||||
Reverse-polarity protection | Yes | |||||||
Ground-Fault isolation detection | 350kΩ Sensitivity | |||||||
Maximum inverter efficiency | % | 98,3 | ||||||
European Weighted efficiency | % | 98,0 | ||||||
Nightime Power Consumption | W | < 12 | ||||||
ADDITIONAL FEATURES | ||||||||
Supported Communication Interfaces | RS485, Ethernet, Built-in GSM (optional) | |||||||
RS485 Surge Protection |
Bulit-in |
|||||||
Rapid Shutdown | Optional (Automatic upon AC Grid Disconnect) | |||||||
Cable covers |
Ordered separately with part number: DCD-SGY-COVER-LP (for SE50K and SE55K) DCD-SGY-COVER-HP (for SE82.8K) ; Dimensions (H x W x D) – 314.3 x 343.7 x 134.5 mm |
|||||||
CONNECTION UNIT | ||||||||
DC Disconnect | 1000 V / 2 x 40 A | 1000 V / 3 x 40 A | ||||||
STANDARD COMPLIANCE | ||||||||
Safety |
IEC-62109, AS3100
|
|||||||
Grid Connection Standards |
VDE-AR-N-4105, G59/3, AS-4777,EN 50438 , CEI-021,VDE 0126-1-1, CEI-016, BDEW |
|||||||
Emissions |
IEC61000-6-2, IEC61000-6-3 , IEC61000-3-11, IEC61000-3-12 |
|||||||
INSTALLATION SPECIFICATIONS | ||||||||
Number of units | 2 | 3 | ||||||
AC Output | mm |
Cable gland — diameter 22-32; PE gland diameter 10-16
|
Cable gland — diameter 30-38; PE mm gland diameter 10-16 |
|||||
DC Input |
6 strings, 4-10mm2 DC wire, gland outer diameter 5-10mm 3 MC4 pairs per unit |
9 strings, 4-10mm2 DC wire, gland outer diameter 5-10mm 3 MC4 pairs per unit |
||||||
AC Output wire | mm2 |
Aluminum or Copper; L, N: Up to 70, PE: Up to 35 |
Aluminum or Copper; L, N: Up to 95, mm2 PE: Up to 50 |
|||||
Dimensions | mm |
Primary Unit: 940 x 315 x 260; Secondary Unit: 540 x 315 x 260
|
||||||
Weight | Kgr |
Primary Unit: 48; Secondary Unit: 45
|
||||||
Noise | dBA | < 60 | ||||||
Operating temperature range | ºC | -40 +60 | ||||||
Cooling | Fan (user replaceable) | |||||||
Protection Rating | IP65 - Outdoor and Indoor | |||||||
Bracked mounted |
Provided |